Laboratory glassware washer is a kind of equipment specially used for cleaning glassware used in the laboratory. It can efficiently remove dirt, grease and residue on the surface of the glassware, ensuring that the cleanliness of the glassware meets the experimental requirements.
The following issues need to be noted when using laboratory glassware washing machines:
1. Choose the right cleaning agent: Choose the right cleaning agent according to the nature and degree of dirt of the glassware to be cleaned. Generally speaking, a special cleaning agent with low foam, easy rinsing and no residue should be selected.
2. The amount of cleaning agent used: Using too much cleaning agent is not only wasteful, but also may cause poor cleaning effect. Therefore, the amount of cleaning agent used should be reasonably controlled according to the instructions for use of the equipment.
3. Cleaning temperature: The cleaning temperature has a great influence on the cleaning effect. Generally speaking, the higher the cleaning temperature, the better the cleaning effect. However, too high a temperature may cause damage to the glassware, so the appropriate cleaning temperature should be selected according to the instructions for use of the equipment.
4. Cleaning time: The length of cleaning time directly affects the cleaning effect. Too short a cleaning time may not be able to completely clean the dirt, while too long a cleaning time may cause unnecessary wear and tear on the glassware. Therefore, the appropriate cleaning time should be selected according to the instructions for use of the equipment. 5. Post-cleaning treatment: After cleaning, the glassware should be taken out in time to avoid long-term immersion in the cleaning agent, which may cause corrosion or discoloration of the glassware. At the same time, the cleaning liquid in the laboratory glassware washing machine should also be discharged to avoid the cleaning liquid remaining inside the equipment and affecting the next cleaning effect.
6. Equipment maintenance: Regularly maintain and maintain it, including cleaning the equipment, replacing the cleaning agent, checking the operating status of the equipment, etc., to ensure the normal operation and cleaning effect of the equipment.
7. Safe operation: When using, the operating procedures should be followed to avoid accidental injuries. For example, when putting in and taking out glassware, you should be careful to avoid glassware breaking and injuring people; when adding cleaning agents, you should avoid contact with skin and eyes, etc.
8. Environmental considerations: When selecting cleaning agents and treating cleaning wastewater, environmental factors should be taken into consideration. Environmentally friendly cleaning agents should be selected as much as possible, and cleaning wastewater should be properly treated to avoid pollution to the environment.
In general, when using a laboratory glassware washing machine, you should pay attention to the above issues to ensure the cleaning effect while protecting the equipment and the environment.